Cybélia IoT : your sensors, watched over
Completed
Alarms and notifications
888 Views •What Cybelia Cloud installs at your premises
883 Views •Signing in
866 Views •Why measure at all
845 Views •The home screen, and finding your way
844 Views •The vocabulary, six words
839 Views •Who is watching while you work
834 Views •Settings, set once
833 Views •Readings and curves
828 Views •When a sensor goes quiet
824 Views •When something sticks: opening a ticket
814 Views •Battery life
808 Views •Who it is for
804 Views •A sensor's record
801 Views •Dashboards
793 Views •The mobile app and looking in from anywhere
785 Views •Users and their permissions
768 Views •History and evidence
757 Views •The estate : the list of sensors
686 Views •Rules : when… then…
679 Views •When a sensor goes quiet
Silence is the real danger
A sensor giving a wrong value can be spotted. A sensor giving nothing at all cannot, and that is far worse, because you carry on believing you are being watched over.
How you notice
Three signs, in this order. On the estate, the time of the last reading that stops moving. On the curve, a blank spreading in from the right. And above all: a dedicated alarm, because a silent sensor deserves to be reported just as much as a crossed threshold.
That is a rule in its own right, and Cybelia Cloud sets it up at installation: "when this sensor has sent nothing for three hours, then raise an alarm". The delay depends on the sensor's normal rhythm, an electricity meter reporting every minute and a humidity probe reporting every quarter of an hour do not have the same patience.
Check that every important sensor has a silence rule. If you only ask Cybelia Cloud one question, ask that one. Without it, a flat battery leaves you blind without a single message.
The causes, from most to least common
The battery, in the vast majority of cases. Then the sensor having been moved: somebody took it down to paint, or a trolley knocked it, and it now sits behind a lump of metal that blocks the radio. Then the gateway: if all the sensors on a site go quiet at once, it is not them, it is the gateway, check it is powered and that the network is working. Finally, rarely, the sensor itself, and it gets replaced.
What you have to do
Nothing technical. Report it, saying whether it is one sensor or several, that is the detail that saves support the most time. Meanwhile the history already recorded is untouched: a silent sensor does not lose the earlier readings.
In closing
A silent sensor is more dangerous than one that is wrong, because you carry on believing you are monitored. That is why silence raises an alarm just as a threshold breach does.
Commenting is not enabled on this course.